  • Lab300

  • Helios-P450

  • Helios-P600

  • Helios-P800

  • SL600

  • SL800

  • Unstable laser power

    Cause 1: The internal crystal temperature parameters of the laser have been changed

    Solution: Contact the manufacturer to calibrate the parameters

    Cause 2: Damage of the window mirror of laser

    Solution: Replace the window mirror of laser

    Cause 3: Unstable environment temperature

    Solution: Ensure the environment temperature is between 22 to 26 degrees


  • Unable to connect the laser

    Cause: Turn on the iBuild and the calibration software at the same time

    Solution: Turn off the iBuild or calibration software and reconnect the laser


  • The iBuild indicates resin level fluctuation error

    Cause 1: The bottom of resin level sensor is dirty

    Solution: Clean the bottom of the resin level sensor

    Cause 2: False angle

    Solution: Adjust the angle of resin level sensor

    Cause 3: Air leakage from the adsorption tube of the vacuum pump

    Solution: Replace the adsorption tube


  • The iBuild alarm “Liquid level is too high or too low”

    Cause 1: The volume of resin in tank is above or below standard and cannot be adjusted by the resin plunger.

    Solution: Add or remove some resin. Cause 2: The resin level sensor has no signal and can’t detect the resin.

    Solution: 1) Clean the bottom of the resin level sensor

    2) Adjust the angle of resin level sensor


  • The iBuild alarm “Laser power is too high or too low”

    Cause: The detected laser power is not within the range of “Power Detection Maximum and Minimum RMS”.

    Solution: 1) Recalibrate the laser power

    2) Modify the “Target Value” or “Power Minimum RMS Value” and “Power Maximum RMS Value” of the laser power


  • RTC4 error

    Cause: Turn on the laser control software and calibration software synchronously

    Solution: Turn off the laser control software or calibration software


  • No laser output

    Cause: Turn on the laser software and calibration software at the same time 

    Solution: Turn off the laser software or calibration software, then restart the iBuild.


  • Laser alarm, the temperature of the laser head is floating, NO laser output

    Cause: The internal crystal temperature parameters of the laser and the environment temperature are unstable

    Solution: Contact the manufacturer to calibrate the parameters and ensure that the environment temperature is between 22 to 26 degrees


  • The size of the same length parts printed at different platform position vary widely

    Cause: Calibration isn’t up to standard
    Solution: Recalibrate

  • Printed samples are assembled too tightly or cannot be assembled

    Cause: The laser beam compensation value is too small, and the reserved space in the design drawing is not enough
    Solution: Modify the laser beam compensation value

  • Printed samples are assembled too loosely and the gap is large

    Cause: The laser beam compensation value is too large
    Solution: Modify the laser beam compensation value

  • Large dimensional deviation of printing parts in Z direction

    Cause: The parameter “Z-axis Compensation” is unreasonable
    Solution: Modify the “Z-axis Compensation” parameter in the slice software setting

  • Large dimensional deviation in XY direction

    Cause: The XY dimension factor in the iBuild is unreasonable
    Solution: 1) Print the “100mm Cross” size test samples, measure the size and recalculate the XY size factor
    2) If the short size is accurate but the long size has a large deviation, set multiple sets of XY coefficients of different sizes or reduce the length of parts over 200mm by 1/1000-2/1000 before printing

  • Deformation of structural printed samples, such as “H” “I” shape

    Cause: The printed samples shrink and deform
    Solution: Adjust the angle when orientate the models

  • There are good textures in two directions, and bad textures in the two directions

    Cause: The variable laser beam appear to be an ellipse
    Solution: Recalibrate the optical circuit

  • The sides of the printed samples are scorched, and the samples have blanks and burrs all around

    Cause: Laser power is too high, resulting in the samples over-curing
    Solution: Appropriately reduce the laser power of the hatch and border

  • The printed sample surface is peeling or bubbling

    Cause: The distance between the border and the hatch is too far
    Solution: Decrease the value of “Transition Area Width” in the iBuild parameters

  • Peeling, blisters appear in only one or two directions around the printed samples

    Cause: The beam is oval or not concentric
    Solution: Recalibrate the light chamber

  • Peeling and bubbling appear at the bottom of the printed samples

    Cause: The distance between the resin level and the recoater is too large
    Solution: 1) Adjust the height of the recoater
    Solution: 2) Reduce the iBuild parameter “Standard Liquid Level Sensor Value” (it is recommended to reduce 0.08-0.1 each time)

  • Irregular horizontal lines appear around the sides of the printed samples

    Cause:The fluctuation of the liquid level value is too drastic
    Solution: 1) Clean the bottom of the liquid level sensor
    2)Adjust the angle of the liquid level sensor
    3)Check if the vacuum pump is leaking

  • “Orange Peel” and “Water Ripples” appear on the side of the printed samples

    Cause: The distance between the border and the hatch is too far
    Solution: Properly increase the “Transition Area Width” in the iBuild settings

  • The samples printed at one time are all broken

    Cause 1: The fluctuation of the liquid level is too drastic
    Solution: 1) Clean the bottom of the liquid level sensor
    2) Adjust the angle of the liquid level sensor
    Cause 2: Low recoater height
    Solution: Adjust the height of the recoater
    Cause 3: There is no adsorption in the recoater
    Solution: Control the recoater adsorption by adjusting the vacuum pump
    Cause 4: The resin is sticky
    Solution: 1) Turn on the heater
    2) Lengthen the time of “Delay after Platform Settling” and “Delay after Recoater Movement” in iBuild settings

  • The printed samples come out with pits on the Surface

    Cause: The surface temperature of the print is too high
    Solutions:1) Reduce the laser power and speed up the scanning
    2) Increase the value of the parameter “Delay after Laser Scanning” in the iBuild

  • The printed samples are staggered or faulted

    Cause 1: The platform is loose or the z-axis coupling is loose
    Solution: Reinstall and locking the platform and the z-axis coupling
    Cause 2: The device is turned on to heat, but the temperature is unstable
    Solution: Turn off the heater and contact the manufacturer.

  • The printed samples are not well formed or the holes details of the printed samples are not well printed out, or the edges are cured with excess flakes

    Cause 1: The lens from reflection mirrors, beam expander module, galvanometer and F-theta are dirty.
    Solution: Inspect the lens and clean it.
    Cause 2: The laser window mirror is damaged
    Solution: Replace the lens of the laser.

  • The printed sample located in a specific position on the platform is partially broken

    Cause: F-Theta is dirty
    Solution: Clean the lens of F-Theta

  • Broken printed samples only appear in the front and back or a corner of the platform

    Cause: The marble platform is not level
    Solution: Adjust the level of the marble platform and adjust the height of the recoater

  • The support is too sticky to the platform, short, and the bottom is obviously wavy

    Cause: The platform is too high when the beginning of the print. 
    Solution: Modify the value of the iBuild parameter “Print Start Position” according to the actual situation

  • The broken parts cause the recoater to be stuck and unable to move, and the software cannot control the movement of the recoater

    Cause: The motor is blocked, causing an alarm
    Solution: Helios-P series (reboot the device)

  • No adsorption in the recoater

    Cause 1.: The adsorption force is small
    Solution: Adjust the knob of the vacuum pump to increase the adsorption force
    Cause 2: The adsorption trachea is blocked or ruptured
    Solution: Replace the adsorption air tube

  • It appears that the support cannot be connected without the coating, and there are many support points floating on the resin surface

    Cause: The support scanning speed is too fast, and the support does not have enough time to reset after coating
    Solution: Appropriately reduce the scanning speed of the support and lengthen the time of the iBuild parameter “Delay after Recoater Movement”

  • Insufficient strength and brittleness of parts

    Cause 1: The samples are over-cured (hard enough)
    Solution: Increase the value of the iBuild parameter “Filling Spacing” to increase the scanning speed
    Cause 2: The samples are not fully cured (slightly soft)
    Solution: Reduce the value of the iBuild parameter “Filling Spacing” to reduce the scanning speed

  • The support is too sticky to the platform, short, and the bottom is obviously wavy

    Cause: The platform is too high when the beginning of the print. 
    Solution: Modify the value of the iBuild parameter “Print Start Position” according to the actual situation

  • The broken parts cause the recoater to be stuck and unable to move, and the software cannot control the movement of the recoater

    Cause: The motor is blocked, causing an alarm
    Solution: Helios-P series (reboot the device)

  • No adsorption in the recoater

    Cause 1.: The adsorption force is small
    Solution: Adjust the knob of the vacuum pump to increase the adsorption force
    Cause 2: The adsorption trachea is blocked or ruptured
    Solution: Replace the adsorption air tube

  • Insufficient strength and brittleness of parts

    Cause 1: The samples are over-cured (hard enough)
    Solution: Increase the value of the iBuild parameter “Filling Spacing” to increase the scanning speed
    Cause 2: The samples are not fully cured (slightly soft)
    Solution: Reduce the value of the iBuild parameter “Filling Spacing” to reduce the scanning speed

<
>
  • Lab300

  • Helios-P450

  • Helios-P600

  • Helios-P800

  • La 600

  • La 800

  • Schon wurden keine Nachrichten hinzugefügt!
描述
  • Schon wurden keine Nachrichten hinzugefügt!
描述
  • Schon wurden keine Nachrichten hinzugefügt!
描述
  • Schon wurden keine Nachrichten hinzugefügt!
描述
  • Schon wurden keine Nachrichten hinzugefügt!
描述
  • Schon wurden keine Nachrichten hinzugefügt!
描述
<
>